H801RC LED Controller
LPD6803, LPD8806, LPD6812, LPD6813, LPD1882, LPD1889, LPD1883, LPD1886, DMX512, HDMX, APA102, P9813, LD1510, LD1512, LD1530, LD1532, UCS6909, UCS6912, UCS1903, UCS1909, UCS1912, WS2801, WS2803, WS2811, DZ2809, SM16716, TLS3001, TLS3002, TM1812, TM1804, TM1803, TM1829, TM1825, DM115C, DM13SC, DM135, DM135, 6B595, MBI6023, MBI6024, MBI5001, MBI5168, MBI5016, MBI5026, MBI5027, TB62726, TB62706, ST2221A, ST2221C, XLT5026, ZQL971, ZQL971.
Piranti lunak tambahan offline yaiku "Perangkat Lunak Mbangun LED";lunak tambahan online punika "LED Studio Software".
(1).Wolung port output drive maksimal 8192 piksel.Nomer piksel sing saben port bisa drive 8192 dibagi nomer nggunakake port.Nomer port bisa dadi siji, loro, papat, utawa wolung.
(2).Makarya online utawa offline, H801RC bisa disambungake menyang komputer, master controller, switch utawa photoelectric converter.
(3).Kinerja sinkronisasi sing dhuwur, tundha transmisi pengontrol budak sing cedhak kurang saka 400 ns, gambar ora ana fenomena tearing utawa mozaik.
(4).Efek kontrol sing apik, skala abu-abu dikontrol kanthi tepat.
(5).Jarak transmisi adoh.Data sing dikirim adhedhasar protokol Ethernet standar lan jarak transmisi nominal antarane pengontrol jejer nganti 100 meter.
(6).Frekuensi mindhai jam bisa diatur saka 100K nganti 50M Hz.
(7).Nggunakake skala abu-abu lan teknologi koreksi gamma inverse kanggo nggawe efek tampilan nyata luwih konsisten karo sensasi fisiologis manungsa.
(1).Sambungake Net1 menyang antarmuka jaringan komputer utawa master, lan Net2 kanggo Net1 saka H801RC sabanjuré.
(2).kabel jaringan Crossover dianjurake ing engineering.Ing ngisor iki urutan wiring.
(3).Nalika nyetel sculpt, sampeyan bisa milih "siji baris karo abdi", "papat baris karo abdi", utawa "wolung baris karo abdi".Nomer baris minangka nomer port.
(4).Ana rong lampu indikator saliyane antarmuka jaringan, sing ndhuwur yaiku NET ijo, sing bakal sumunar nalika H801RC ndeteksi data saka kabel jaringan, ing ngisor iki yaiku ACT abang, sing bakal sumunar nalika data output controller menyang lampu.Frekuensi lampu kilat ditindakake kanthi kacepetan ngirim data.
(5).Nalika H801RC disambungake menyang komputer, aja milih "entuk alamat IP kanthi otomatis" nanging pilih "Gunakake alamat IP ing ngisor iki", ketik alamat IP kaya ing ngisor iki, Subnet mask yaiku 255.255.255.0, elinga mriksa "validasi setelan nalika metu" .
Gunakake serat optik kanggo ndawakake jarak ngirim
Tegangan Input | AC 220 V |
Konsumsi Daya | 1.5W |
Piksel drive | 8192 |
Bobot | 1 Kg |
Suhu Kerja | -20C°--75C° |
ukuran | L189 x W123 x H40 |
Jarak Lubuk Instalasi | 100 mm |
Ukuran Karton | L205 x W168 x H69 |